Sale!

SPU100-50 100,000 BTU 50′ Total Emitter Tube Length ‘U’ Shaped

Brand: SunStar

$1,655.00 $1,517.10

SPU100-50 100,000 BTU 50′ Total Emitter Tube Length ‘U’ Shaped – Min mounting height at horizontal of 14″ FT

Usually ships in 5-8 Days

Clear

Product Add-Ons

Compare
SKU: SPU100-50 Categories: ,

Description

SPU Series – For Commercial/Industrial Use Only

The Economical Alternative for Hard-to-Heat Spaces

Whether you need to heat your warehouse, garage, or other hard-to-heat spaces, the SunStar SPS/U Series infrared heaters provide both the field efficiency of radiant heat and the installation flexibility you need…and all at a comfortable price.

  • Push Through System
  • 8 different Btu sizes and more than 60 different configurations to custom design your infrared heating system
  • CSA design certified
  • Available in natural and propane gas
  • Optional elbows and corner reflectors
  • Optional decorative grille
  • Sidewall or through the roof venting
  • Vented or indirect vented operation
  • Includes 36″ stainless steel gas connector

 

Introducing TISS™ Tube Integrity Safety Shut-Off System

TISS™ Tube Integrity Safety Shut-Off SystemSunStar’s patent pending innovative safety feature for positive pressure radiant tube heaters is called the “Tube Integrity Safety System” (TISS™).

In the unlikely event of a tube failure, TISS™ has been designed to automatically shut off the heater. The revolutionary TISS™ uses a simple principle to place an electrically insulated aluminum wire in tension above the reflector. Low voltage is then continuously passed along the wire in line with the gas control circuit. If heat levels increase due to heat exchanger failure, the wire melts and the safety circuit is broken, breaking the 24 volt circuit and shutting down the heater.

You may never know it is there, but it provides peace of mind.

SPU Dimensions

ModelTotal Tube LengthOverall Dimensions “L” (FT)
SPU (40, 50, 75)20′12′ 9″
SPU (50, 75, 100, 125)30′17′ 9″‘
SPU (100,125, 150, 175)40′22′ 9″
SPU (125, 150, 175, 200)50′27′ 9″
SPU (150, 175, 200)60′32′ 9″
SPU (175, 200)70′37′ 9″

SPU Dimensions - Bottom View SPU Dimensions - End View

ModelBTU/HR InputTotal Emitter Tube Length
20 FT.30 FT.40 FT.50 FT.60 FT.70 FT.
SPU 4040,000
SPU 5050,000
SPU 7575,000
SPU 100100,000
SPU 125125,000
SPU 150150,000
SPU 175175,000
SPU 200200,000

*Model number is based on Btu/hr input (e.g., 100,000 Btu/hr), total emitter length (e.g., 40 feet) and control suffix for gas type (eg. natural gas-single stage-N5 or two stage-N7). For example, the model number for a straight tube single stage heater would be SPS100-40-N5 and for a U-tube heater would be SPU100-40-N5.

Tough Guy Option: All aluminized steel radiant tubes
For Tough Guy option the model number would be SPU100-40-TG-N5. Note: for Carwashes, Dairy Barns, Greenhouses, Swimming Pools, Waste Water Treatment Plants, and other high humidity / corrosive environments, Tough Guy with all aluminized tubes is recommended.

SPS & SPU Burner Box Dimensions

SIU, SPU U Bend Reflector Dimensions

SPU Supply Requirements

Gas TypeBurner PressureSupply PressureVoltageAmpsIgnition Type
MINMAX
Natural3.5″ W.C.5″ W.C.14″ W.C.120 VAC 60 Hz2.4Direct Spark
Propane10″ W.C.11″ W.C.14″ W.C.120 VAC 60 Hz2.4Direct Spark

SPU Minimum Mounting Heights

ModelHeight at HorizontalHeight at 45° Angle
SPU 4010′9′
SPU 5011′10′
SPU 7513′12′
SPU 10014′13′
SPU 12514′13′
SPU 15015′14′
SPU 17516′15′
SPU 20018′16′

SPU Minimum Mounting Heights

SPU Clearances to Combustibles

ModelSideCeiling*BelowEnd(45°) Front(45°) Rear
SPU 4022″6″52″15″40″12″
SPU 5022″6″56″15″48″12″
SPU 7522″6″60″15″52″12″
SPU 10028″6″70″ **15″58″12″
SPU 12528″6″76″ **20″66″12″
SPU 15034″6″81″ **20″70″12″
SPU 17538″6″86″ **20″75″12″
SPU 20042″6″93″ **20″80″12″

* When used indirect vented, minimum clearance for Ceiling must be: 12″ for SPU 40-75, and 18″ for SPU 100-200. If optional corner and u-bend reflectors are not used, the clearance must be 18″.

** Maximum clearance below reduces by 50% once you are 25ft. downstream from the burner box.

SPU Clearances to Combustables

PDF Icon
Specifications
PDF Icon
Installation Manual
PDF Icon
Accessories