Gordo Sales, Inc. 'Heat & Control Specialists'; Outside Salt Lake City, UT, Phone: 801-544-4236

 

 
temperature controler, cartridge heater, band heater, immersion heater, tubular heater, etc.
Terms  Products  Site Map  Feedback  Search   Contact Order Status  


TEMPERATURE SENSORS
Silicone Rubber Heaters can be fabricated with thermostats, thermocouples, RTD's and thermal fuses as an integral part of the heater.
Sensors can be located to monitor either heater sheath or part temperature. Small sensors have a protective cap of silicone sheath material vulcanized to the heater body. Large sensors and thermostats have a solid silicone rubber overmold, also vulcanized to the heater.
STANDARD THERMOSTATS
Model
Max.
Watts
Volts
AC
Preset
Range deg. F
H300
300
120/240
80 - 300 +/- 5
H800
800
120/240
80 - 300 +/- 5
H1500*
1500
120
40 - 500 +/- 5
2400
240
40 - 500 +/- 5
*Snap action, wide differential
Other sizes and ratings upon request


BONDING METHODS

Factory Vulcanizing:
The silicone rubber heater is vulcanized directly to your part during manufacture of the heater. This produces a very strong, void-free bond between heater and part that gives the best possible heat transfer and extended heater life. When other methods of bonding have caused heater failure, factory vulcanizing can solve the problem. Also, maximum watt densities can be utilized to reduce heater size, thereby lowering cost.

Silicone Rubber Adhesive:
For a strong, permanent bond, a curing-type silicone rubber adhesive should be used. Heaters can be bonded to your parts at our factory, or we will supply recommendations for proper application.

U L Component Recognition

Hi-Heat participates in Underwriters' Laboratories Component Recognition program, under UL's File N. E95403. Under the file, A UL constructed heater can operate in an application with a sheath temperature of 200 deg. C.

Lead arrangements and controls will have to be evaluated for each application - Hi-Heat will work with designers and manufacturers to design heaters that fulfill application requirements and meet UL requirements for very special applications. Consult the factor for alternate constructions.
 

Gordo Sales, Inc.  "Heat and Control Specialists" 

PO Box 1166, Layton, UT 84041 (801) 544-4236
Copyright 2002

For any questions (application, technical, availability) please call us at (801) 544-4236 between 8am and 5pm Monday - Friday mountain time