Gordo Sales, Inc. 'Heat & Control Specialists'; Outside Salt Lake City, UT, Phone: 801-544-4236

 

 
temperature controler, cartridge heater, band heater, immersion heater, tubular heater, etc.
Terms  Products  Site Map  Feedback  Search   Contact Order Status  

 

MIGHTY-BLADE FORMING

The unheated area from the termination end to the initial bend along with minimum dimensional requirements are primary considerations when forming a Mighty-Blade element. Parameters of the five possible types of bends are shown for use when designing a Mighty-Blade.

click on any Axis Bends to enlarge
Tolerances and Limitations:
Width: 1.0" + .015" -.010"
Thickness: .275" ±.005"
Minimum Sheath Length: 12"
Maximum Sheath Length: 180"
Maximum Voltage: 480
Maximum Amps: 40
Minimum Ohms/In. of EHL:
Mini2 coil element, .075 ohms;
Mini3 coil element, .05 ohms
Maximum Ohms/In. of EHL:
Mini2 coil element, 3.5 ohms;
Mini3 coil element, 2.33 ohms
Unheated Area Each End: 1" minimum; 12" maximum
Wattage: +5 -10%
Resistance: +10 -5%
Sheath Length: ±1/2%
Effective Heated Length: ±1%

click on any Type to enlarge
 

Gordo Sales, Inc.  "Heat and Control Specialists" 

PO Box 1166, Layton, UT 84041 (801) 544-4236
Copyright 2002

For any questions (application, technical, availability) please call us at (801) 544-4236 between 8am and 5pm Monday - Friday mountain time